• During use, always place the unit on a firm surface clear of obstacles.
• Check that there is no material obstructing the air vents before each use.
• Do not place any objects inside the air vents.
• Repairs must be performed by authorized personnel only. Any unauthorized repairs will void the
warranty and may pose a safety hazard for the user.
WARNING: Do not modify this equipment without authorization of the manufacturer
• The average duration provided for compressor ranges is: F400: 400 hours, F700: 700 hours, F1000:
1000 hours, F2000: 2000 hours.
• The Manufacturer, the Retailer and the Importer are responsible for the safety, reliability and
performance of the device only if: a) the device is used in accordance with the operating instructions
b) the electrical system of the premises where the device is used is in compliance with current laws.
• Interactions: The materials used that come into contact with medications have been tested with a
wide range of medications. However, due to the variety and continuous evolution of medication,
the possibility of a chemical interaction cannot be excluded. We recommend that once the
medication has been opened you should use it as soon as possible and avoid prolonged contact of
the medication with the nebulizer.
• The manufacturer should be contacted for reporting problems and/or unexpected events related to
device operation.
OPErATIng InSTrUCTIOnS
Before each use, clean hands thoroughly and clean the device as described in the section on
"CLEAnIng, SAnITIZATIOn AnD DISInFECTIOn". During use, it is advisable to protect yourself
from any dripping. It is recommended that each person use their own nebulizer cup and
accessories to prevent risk of infection due to contamination.
1. Plug the power cord (A6) into a power socket corresponding to the voltage of the unit. This must be
positioned so that it is not difficult to make the disconnection from the mains.
2. Open the nebulizer by turning the top piece (C1.3) anticlockwise.
3. P our the medicine prescribed by your physician in the bottom piece (C1.1). Close the nebulizer by
turning the top piece (C1.3) clockwise.
4. Connect accessories as indicated in the "Connection diagram" on the cover.
5. Sit comfortably holding the nebuliser in your hand, place the mouthpiece onto your mouth or
alternatively use the nose piece
HOW TO USE THE "rF7 DUAL SPEED PLUS" nEBULIZEr WITH SPEED SELECTOr AnD
VALVE SySTEM
Professional and fast, this device is suitable for administering all types of medications,
including more expensive ones, even in patients with chronic diseases. The
geometry of the internal lines of the RF7 Dual Speed Plus nebulizer ensures the ideal
granulometry for active treatment all the way down to the lower respiratory tract.
To speed up the inhalation therapy, move the speed selector button (C1.4) by
pressing on MAX with your finger.
For a more effective inhalation therapy, press on the opposite side of the word Max
located on the speed selector button (C1.4); this allows you to inhale an optimal
amount of the medication and reduces dispersion of the medication into the
surrounding environment to a minimum thanks to the valve system provided in the
nebulizer, mouthpiece, and mask.
or mask. Should you opt for the mask accessory, place it on
your face as shown in the picture (with or without using the
elasticated strap).
6. T urn on the device using the switch (A1) and then breathe in
and exhale deeply.
7. W hen the treatment is finished, shut off the device and unplug
the power cord.
WARNING: If after the therapy session moisture accumulates in
the tube (B), remove the tube from the nebulizer and dry it using
the device's compressor fan; this operation will prevent mold from
forming inside the tube.