Cleaning Controls; Lighting Maintenance; Electrical Connections; How To Connect The Cables To The Batteries - Quickie Jive M2 Sedeo Ergo Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

14.4.2 Cleaning controls

Should the control of your wheelchair become soiled or dirty, it
can be wiped with a damp cloth with a dilute disinfectant until
clean.
WARNING!
This is important should the wheelchair be used by more than
one person to ensure there is no cross infection.
Speciality controls
WARNING!
• Ensure that wafer boards, joysticks (all variants), head
arrays and switches (all variants) are cleaned with a mild
disinfectant and a cleaning cloth to avoid any cross infection
possibilities. Following removal from chair regularly wash the
sip and puff mouth piece and tube to maintain cleanliness
and functionality.
• Ensure control is switched off before cleaning.

14.5 Lighting maintenance

WARNING!
Maintaining lights and indicators is a safety critical task. If your
lights and indicator system shows a defect, please contact your
Sunrise Medical Approved Dealer.
All lights and indicators are state of the art LED low energy,
no maintenance units. There are no light bulbs used. The high
intrinsic reliability of these units means that they are extremely
unlikely to fail under normal usage. If a failure should occur,
(may be as a result of an impact), the damaged light assembly
must be replaced in its entirety. The individual LED's cannot
be replaced.
CAUTION!
We recommend the use of Sunrise Medical authorised spare
parts only.
NOTE: Be advised that all lighting circuits are electronically
protect ed. In the event of a short circuit current will be limited
to a safe level. Once the fault is removed the system resets
automatically.

14.6 Electrical connections

When inspecting electrical connections, pay attention to the
battery connections, the connection of batteries to power loom
and plug in sockets for the joystick, control box and lights and
indicators.
Rev. 2.0

14.7 How to connect the cables to the batteries

WARNING!
If you are in any doubt about performing any maintenance
on your wheelchair, please contact your Sunrise Medical
authorised dealer.
Parts in the battery box:
Two 12v Deep Cycle Mobility Batteries.
Two Fused Battery Loom Assemblies.
One Power Loom
WARNING!
Before connecting the batteries it is very important to
identify the correct connection for each battery terminal.
Failure to do this may result in the wheelchair not
functioning or possibly a blown fuse.
Connect all battery terminals before connecting the plugs.
After connecting battery terminals and connectors ensure
all wiring is tidy and can not get entangled in any moving
parts and the rubber covers fit fully over the battery
terminals.
NOTE: After connection of the batteries wait 2 minutes for
the system to reset, before switching on the control system.
This reset time is required every time the batteries are
disconnected.
Connecting / Disconnecting the Batteries:
(Fig.14.19 - 14.24 Next page).
Undo the two seat interface screws, (Section 12.1).
Flip the seat frame backwards until the automatic lock
pin clicks to secure it in place. Ensure the seat is secure
before letting go, (Fig.14.19).
Lift off the battery box lid, (Fig.14.19).
The Front battery has RED to Positive (+) & BLACK to
negative (-). (Fig.14.20 - 14.21).
The Rear battery has RED to Positive (+) & BLACK to
negative (-). (Fig.14.20 - 14.21).
Connect the GREY plugs to the power loom, (Fig.14.22 -
14.23).
WARNING!
Ensure the two seat interface screws are fully tightened before
using the wheelchair, (Section 12.1, Fig.12.1).
49
Jive M2 Sedeo Ergo

Publicité

Table des Matières
loading

Table des Matières