Setting The Scald Protector - Franke AQCT0073 Notice De Montage Et De Mise En Service

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

An application time of 3, 5, 10, 15, or 20 minutes can be chosen for the thermal
disinfection process. During the application time, water flows without interruption for
2 minutes; the water then flows in pulses until the end of the application time (water
and energy saving function). The cooling time can be set to 0, 1, 3, 5, or 10 minutes.
Required accessories
Bypass solenoid valve cartridge . . . . 2000109499

16. Setting the scald protector

Warning!
If the hot water supply temperature is above 45°C, the scald protector should be set.
Failure to observe this instruction can result in injuries due to scalding.
The scald protector (hot water stop) has been set to 38°C at the factory. Set the
system-specific parameters before use.
16.1 Remove the cover platelet (d).
16.2 Release the screw (c) with its disk.
16.3 Remove the temperature selector (b).
16.4 Remove the stop ring (a).
16.5 Trigger the fitting.
16.6 The temperature is freely selectable:
Set the maximum water temperature on the adjustment nut (e), e.g. to 40 °C.
16.7 Mount the stop ring (a) in such a way that the marking (h) of the stop ring points to
the outer edge of the red marking (g) of the rosette (f).
Important!
Mount the temperature selector (b) in such a way that the stop is flush against the
stop ring crosspiece.
16.8 Slide the temperature selector (b) onto the stop ring (a).
16.9 Attach the temperature selector (m) and its screw (n) and disk to the fitting.
Tightening torque: 1 Nm
16.10 Fit the small cover plate (w).
- 11 -

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Aqct007676129822191087612982219139

Table des Matières