Dometic MCS5 Notice De Montage page 19

Masquer les pouces Voir aussi pour MCS5:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 55
_IA_MCS.book Seite 19 Mittwoch, 28. Januar 2009 9:06 09
MCS5, MCS15
8.3.2
MCS15
The auxiliary vertical-support bracket must be used when the blower is
vertical or unit damage will occur, voiding the warranty.
Note
I
Self-tapping screws will drill their own pilot holes if a screw gun is used,
but if pilot holes are necessary, utilize a 0.5 mm drill bit with a drill stop or
other method to block the drill bit from going deeper than 6 mm into the
blower housing, as the fan blade will be damaged.
Remove and discard the 2 self-tapping screws that attach the blower
to the drain pan.
Remove wire tie holding blower wire harness to base pan and/or
adjacent harness.
Remove and save the 7 screws (fig. 4 5, page 4) holding the blower
plate to the evaporator shroud.
Rotate the blower 90° so the discharge is in the vertical position and
aimed upward.
Reinstall the 7 screws to hold the blower plate to the evaporator
shroud.
Locate the auxilliary vertical support bracket (fig. 4 3A and 3B,
page 4) attached to the pan.
Remove and save the 2 screws (fig. 4 2, page 4) in the end A
(fig. 4 3A, page 4).
Remove and save the 2 self-tapping screws (fig. 4 4, page 4) that at-
tach blower to drain pan.
Using the 2 screws you just removed from the end A, mount the end A
to the inside of the pan (fig. 4 6, page 4).
Using 2 of the self-tapping screws you just removed, mount the end B
(fig. 4 3B, page 4) of the bracket to the blower housing (fig. 4 7,
page 4).
Make sure the power wire is repositioned so it will not catch on any-
thing during or after installation.
The vertical rotation is complete.
Installation
19

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Mcs15