DC Current (Autorranging for uA and mA)
Range
400.0uA
4000uA
40.00mA
400.0mA
10A
Overload Protection: 0.5A / 250V and 10A / 250V fuse.
Maximum Input: 400mA DC or 400mA AC rms on uA / mA ranges, 10A DC or AC rms on 10A range.
AC Current (Autoranging for uA and mA)
Range
400.0uA
4000uA
40.00mA
400.0mA
10A
Overload Protection: 0.5A / 250V and 10A / 250V Fuse.
Frequency Range: 50 to 400 Hz
Maximum Input: 400mA DC or 400mA AC rms on uA / mA ranges, 10A DC or AC rms on 10A range.
Resistance (Autoranging)
Range
400.0
4.000k
40.00k
400.0k
4.000M
40.00M
Input Protection: 250VDC or 250VAC rms.
Capacitance (Autoranging)
Range
4.000nF
40.00nF
400.0nF
4.000uF
40.00uF
200.0uF
Input Protection: 250VDC or 250VAC rms.
DVM9912
Resolution
0.1uA
1uA
10uA
100uA
10mA
Resolution
0.1uA
1uA
10uA
100uA
10mA
Resolution
0.1
1
10
100
1k
10k
Resolution
1pF
10pF
0.1nF
1nF
10nF
0.1uF
Accuracy
+1.0% of rdg + 3 dgts
+1.5% of rdg + 3 dgts
+2.5% of rdg + 5 dgts
Accuracy
+1.5% of rdg + 5 dgts
+1.8% of rdg + 5 dgts
+3.0% of rdg + 7 dgts
Accuracy
+1.2% of rdg + 4 dgts
+1.0% of rdg + 2 dgts
+1.2% of rdg + 2 dgts
+2.0% of rdg + 3 dgts
Accuracy
+5.0% of rdg+50 dgts
+5.0% of rdg + 7 dgts
+3.0% of rdg + 5 dgts
+5.0% of rdg + 5 dgts
11