BATTERY REPLACEMENT

WARNING: To avoid electric shock, disconnect the test leads from any source of voltage before
removing the battery door.
1. When the batteries are exhausted or drop below the operating voltage, "BAT" will appear in the right-hand
side of the LCD display. The battery should be replaced.
2. Follow instructions for installing a battery. See the battery installation section of this manual.
3. Dispose of the old battery properly.
WARNING: To avoid electric shock, do not operate your meter until the battery door is in place and
fastened securely.

BATTERY INSTALLATION

WARNING: To avoid electric shock, disconnect the test leads from any source of voltage before
removing the battery door.
1. Disconnect the test leads from the meter.
2. Open the battery door by loosening the screw using a Phillips head screwdriver.
3. Insert the battery into battery holder, observing the correct polarity.
4. Put the battery door back in place. Secure with the two screws.
WARNING: To avoid electric shock, do not operate your meter until the battery door is in place and
fastened securely.
NOTE: If your meter does not work properly, check the fuses and battery to make sure that they are still in
good operating condition and that they are properly inserted.

REPLACING THE FUSES

WARNING: To avoid electric shock, disconnect the test leads from any source of voltage before
removing the fuse door.
1. Disconnect the test leads from the meter and any item under test.
2. Open the fuse door by loosening the screw on the door using a Phillips head screwdriver.
3. Remove the old fuse from its holder by gently pulling it out.
4. Install the new fuse into the holder.
5. Always use a fuse of the proper size and value (0.5A/250V fast blow for the 400mA range, 10A/250V fast
blow for the 10A range).
Put the fuse door back in place. Insert the screw and tighten it securely.
WARNING: To avoid electric shock, do not operate your meter until the fuse door is in place and fastened
securely.