Technical Data - EINHELL HGG 110 Instructions De Service

Générateur d'air chaud
Table des Matières

Publicité

Anleitung HGG 110-171-300_SPK7:_
GB

8. Technical Data

HGG 110
HGG 110 Niro
Nominal heat load Qu:
max. (Hi) 11,2 kW
Air throughput:
500 m
Connection:
G 30: 815 g/h
Equipment category:
I3B/P
Country of destination
DE, AT, CH, PT, ES,
SE, IT, DK, NO, FI, FR,
GB, CZ, HU, BE, PL,
BG
Type of gas:
commercially
available propane
(DIN 51622)
commercially
available butane
(DIN 51622)
Operating pressure P:
300 mbar
(Propan/Butan)
Power supply:
230 V ~ 50 Hz, 0,17 A,
38 W
Equipment category:
IP44
Air temperature class:
57°C
12
03.04.2009
10:52 Uhr
HGG 171 Niro
max. (Hi) 17 kW
3
/h
500 m
3
/h
G 30: 1430g/h
I3B/P
DE, AT, CH, PT, ES,
SE, IT, DK, NO, FI, FR,
GB, CZ, HU, BE, PL,
BG
commercially available
propane (DIN 51622)
commercially available
butane (DIN 51622)
300 mbar
(Propan/Butan)
230 V ~ 50 Hz, 0,17 A,
38 W
IP44
75°C
Seite 12
HGG 300 Niro
max. (Hi) 30 kW
500 m
3
/h
G 31: 2150 g/h
I3P
DE, AT, CH, PT, ES,
SE, IT, DK, NO, FI, FR,
GB, CZ, HU, BE, PL,
BG
commercially available
propane (DIN 51622)
1500 mbar (Propan)
230 V ~ 50 Hz, 0,17 A,
38 W
IP44
76°C

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Hgg 110 exHgg 110 niroHgg 110 niro exHgg 171 niroHgg 171 niro exHgg 300 niro ... Afficher tout

Table des Matières