Tabelle 10:
Malfunction
No outlet pressure available
Outlet pressure too low
Outlet pressure less than the
set point
Outlet pressure does not
correspond to the stipulated
set point
ED05 pressure regulator does
not exhaust
Green POWER LED not
illuminated
Green POWER LED
flashing
AVENTICS | ED05 | R414002533–BAL–001–AG

11 If malfunctions occur

Possible cause
No power supply
No set point stipulated
No supply pressure available
Supply pressure too low
Consumers that use a lot of
air (> 1000 Nl/min) cause a large
drop in pressure in the device
Housing ventilation port is closed
Exhaust connection is closed
No voltage available
Undervoltage
If malfunctions occur
Remedy
Connect the power supply
Check the polarization of the
power supply
Switch on system component
Stipulate a set point
Connect the supply pressure
Increase the supply pressure
Reduce air consumption
Use a device with a larger
nominal width (e.g. ED07)
Ensure that the housing
ventilation port is open
Open the exhaust connection and
connect a silencer or restricted
exhaust hose
Check power supply at the
integrated M12 plug
Check power supply at the
integrated M12 plug