SAW BLADE MOUNTING AND DISMOUNTING

WARNING:
To prevent an accident or personal injury, always turn off the trigger switch and disconnect
the power plug from the receptacle before removing or installing a saw blade.
1. M ounting the sa w blade
(1) Rotate blade guard (plastic), to top position.
(2) Loosen 5 m m scre w to free cutter shaft guard.
A nd rotate cutter shaft guard to the up position as sho w n in Fig. 36-b.
At that tim e, the blade guard (plastic) m ove together.
(3) Press in spindle lock and loosen bolt with wrench.
Since the bolt is left-hand threaded, loosen by turning it to the right as sho w n in Fig. 36-b.
NOTE:
If the spindle lock cannot be easily pressed in to lock the arbor shaft, turn the bolt with
wrench while applying pressure on the spindle lock.
The arbor shaft is locked when the spindle lock is pressed inward.
(4) Re m ove the bolt and arbor collar.
Spindle
Lock
Sa w Blade
Blade Washer
Bolt
Spot Facing
(5) M ount the sa w blade.
WARNING:
(6) Thoroughly clean collar, arbor collar, blade w asher (confirm m ounting direction) and the bolt, and
install the m onto the arbor shaft as sho w n in Fig. 36-c.
(7) Press in the spindle lock and tighten the bolt by turning it to the left by wrench as indicated in Fig.
36-b.
CAUTION:
(8) Rotate the cutter shaft guard to the initial position and tighten 5 m m scre w.
(9) Place blade guard (plastic) in the do w n position.
20
Fig. 36-a
Arbor
Collar
Collar
Fig. 36-c
When mounting the saw blade, confirm that the rotation indicator mark on the saw
blade and the rotation direction of the blade guard (metal) are properly matched.
* Confirm that the spindle lock has returned to the retract position after installing or
removing the saw blade.
* Tighten the bolt so it does not come loose during operation.
Confirm the bolt has been properly tightened before the power tool is started.
Tighten
Loosen
Arbor Shaft
Sa w Blade
Blade G uard
(Plastic)
Cutter Shaft
G uard
5 m m Scre w
U p
Arbor Collar
Wrench
Bolt
Fig. 36-b