Eaton CROUSE-HINDS Série Mode D'emploi page 11

Masquer les pouces Voir aussi pour CROUSE-HINDS Série:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

7 . Close the base and the search light, pressing carefully on the side
walls of the base (fig. 5, item 2).
8. Tighten the socket head screw (test torque ca. 1.0 Nm).
9. Put into operation again for the first time as described in section 5.2.
10. Charge the portable search light as described in section 5.3.
Operation and fault indication
1. Charging for the first time (before commissioning)
red LED
green LED
V
g
g
g
V
2. Charging
V
V V V
V
V V
V
V
V
V
3. Operation
V
V
V
V
V V
V
V V V
V
V V V V
V
V V V V
4. Fault indication
,
V V V V
v
V V V V
Legend:
V
red/green LED off
Explosion protected portable search light
SEB 10, SEB 10 L
battery capacity
function
0 %
green sequential light
g First-time initialization after connection of the battery.
First-time charging of battery for max. 8 hours,
after which a full charge is indicated.
100 %
constant green light
g Battery has been charged, full capacity available.
< 25 %
green LED flashing
g Charging mode: Battery is being charged.
< 50 %
< 75 %
< 100 %
100 %
four green LEDs light up
g Battery has been charged, full capacity is available.
75 - 100%
green LEDs light up continuously
g Discharging mode:
50 - 75%
Portable search light in operation
25 - 50%
0 - 25%
< 10%
green LEDs off
g Safety circuit: after search or work light flashes 5 times,
switchover to approx. 50% of the rated luminous flux for up to 60
minutes.
0%
green LEDs off
g Battery completely discharged.
red LED flashes, green LEDs off
g Fault message: electronics malfunction
Switching-off of all light functions.
red LED on
g Fault message: battery malfunction.
,
v
red LED on
red LED flashing
green LED on
green LED flashing
7.
Repairs / Maintenance / Modifications
Original spare parts from COOPER CROUSE-HINDS GmbH/CEAG only
may be used for maintenance / repair work.
Repairs that affect the explosion protection may only be carried
out by CCH or a qualified electrician in compliance with the
applicable national rules and IEC/EN 60079-19.
Modifications or changes to equipment are not permitted.
8.
Disposal/Recycling
The national regulations for waste disposal shall be taken into consideration.
GB
action
none
none
none
none
none
leave the hazardous
area
recharge light
send in light for repairs
replacement of battery
necessary
11

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Seb 10Seb 10 l

Table des Matières