Description; Operation - Dustcontrol DC 2900 a Notice Originale

Machine qui doit être utilisée pour l'aspiration et la séparation des poussières sèches
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 25

Description

The machine should be used for suction and sepa-
ration of drie dust. The machine fulfi ls the demand
of separation of unhealthy dust.
The dust extractor is, despite its compact size,
a full capacity Dustcontrol machine. It is stable,
tough, reliable and particularly suited to spot ex-
traction in many different applications e.g. welding,
grinding, sanding and cleanup with the 38 mm
program. Dust separation is as effi cient as with the
larger Dustcontrol machines.

Operation

Connect the unit to a suitable power
source, note requirements on the ID
plate. If an extension cord is to be
used; It must be waterproof.
Auto: Connect the subject electric tool
to the electrical outlet on unit. Set the
selector switch to the AUTO position.
The unit will start automatically when
the subject tool is started. The machine
turns off a few seconds after the con-
nected tool is closed.
Man: For manual start of the unit, set
the selector switch to the MAN position.
The machine has a fi lter indicator light that lights
up when the fl ow is approaching 20 m/s (Ø 50) and
means that the fi lter needs to be cleaned or chan-
ged. The fi lter is generally cleaned once or twice
daily during normal continuous operation. The unit
must be in operation to perform fi lter cleaning.
Losen the tube from the suction pipe and press
the plastic cage against the black stop head on
the exhaust channel so that maximum pressure is
created in the cyclone.
Open the port on the side of the unit three to six times.
This reverse pulse of air cleans the fi lter.
The design is ergonomic and appealing. With a
very low sound level of 68 dB(A) at 1 m distance,
the
The machine is suitable for use in areas which are
sensitive to noise. The direct drive two stage high
pressure fan is integrated into the top. The fan is
double insulated for higher safety.
DC 2900c - plastic bag
The plastic bag should be changed only after the
fi lter is cleaned and when the collected material
level is about 5 cm under the foot valve.
Use only original Dustcontrol spare parts.
DC 2900a - container
The container under the cyclone should be emptied
when approx. 2/3 full.
DC 2900, 15
Part No 94164-E

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Dc 2900cDc 2900

Table des Matières