Description; Operation - Dustcontrol DC 5800c PTFE Manuel D'instruction

Masquer les pouces Voir aussi pour DC 5800c PTFE:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Description

The DC 5800c is an electric powered vacuum ex-
tractor for use with source extraction, cleaning and
material transportation applications in most types of
industries.
The extraction system functions with negative pres-
sure (vacuum) that draws the air through suction
casings, nozzles, hose systems, separator and fi lter
systems. Coarse separation of dust occurs in the unit's
When emptying the container, it is unclipped
and removed away from the machine. After
that has be done the sack can be taken out of
the container.

Operation

Connect the machine to a suitable power source
by following the specifi cations found on the serial
number plate on the machine. If an extension cord
is to be used with the unit, it should be suitably rated
according to the prevailing electrical code. Check
rotation of the motor at startup. On machines equip-
ped with a phase reverser, incorrect rotation can be
easily changed. Machines not equipped with a phase
reverser will require the service of a qualifi ed electri-
cian to interchange two phases in the power supply.
The fi lter should be cleaned 1-2 times per day with
continuous running, or if the machine is equipped
with a fi lter monitor, when this is in the red area.
For fi lter cleaning:
cyclone which is a highly effi cient separator for larger
particulate. The fi ne dust is separated and contained
by the unit's fi lter system. Separated material is col-
lected for disposal in the plastic sack or container at
the base of the cyclone.
Filter cleaning with reverse pulse gives long fi lter
life and constant capacity.
The container is attached to the machine
by two fasteners.
1. Start the machine.
2. Close the shutter valve on the machines inlet.
3. With slow, even motion open the pulse top by
lifting the handle. Repeat three to six times.
4. Open the shutter valve.
5. If the fi lter condition meter reads green work
can continue, if in the red, pulse clean again. If
after several repetitions, the fi lter condition still
shows red the main fi lter must be changed.
The plastic sack should be changed only after the
fi lter has been cleaned. The sack should be changed
when the dust level is about 20 cm under the edge
of the container. The plastic sack should be sealed
after removal from the machine. Use only original
plastic sacks.
DC 5800c PTFE 5 kW - 9
Part No 9475

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

9475

Table des Matières