Counter Installations

Units placed on a counter must either use legs or be
sealed to the counter top with food grade sealant per
local codes. To avoid disturbing the seal, complete the
installation prior to sealing.
Note: Seal
Chassis to
Counter, do NOT
Seal Drip Tray
Legs
10.2 cm legs are optional for countertop applications.
They are not to be used on the HID dispenser when it
is placed on a machine stand.
Note: Use only
legs of 10.2 cm
minimum height.
Set Up
The drip tray and cup rest are shipped in place, there
is no need to attach or remove them. It is a good idea
to remove the front panels and inspect for any loose
or rubbing parts prior to installation.
Panel Removal
Remove one screw at bottom front of upper front
panel, swing bottom of panel forward and lift off the
unit.
Twist ice and
water chutes
counterclockwise and
pull down to remove.
Remove four screws
from sides of lower
front panel, pull forward
slightly and rest it
on the drip tray. If
needed, unplug sensor
connector and separate
panel from unit.
Pre-Start Inspection
Level the cabinet front to back and left to right.
Confirm there are no loose or rubbing parts.
Return splash panel and chutes to unit.