o Full Colour 2
An alternative full colour scheme that expands to cover the dynamic range of
the scene.
o Full Colour 3
An alternative full colour scheme that expands to cover the dynamic range of
the scene.
o Green Scale
Basic green scale colour scheme that expands to cover the dynamic range
of the scene.
Direct Temperature Measurement
temperature reading is displayed in the bottom right-hand corner of the display.
This system is intended to give the operator the ability to detect possible
hazards such as hot gas bottles or tanks.
The camera can be configured to give a reading in degrees Celsius or degrees
Fahrenheit by using the user software or the remote control. Scene
temperatures between -40 and +800 °C (-40 and +1472 °F) can be displayed.
TM
4 HR320: -40 and +1000 °C; -40 and +1832 °F). This feature can be
(Argus
turned off if not required by using the software provided.
Note: If the object in the scene does not fully fill the target marks then a false
reading may be obtained.
Different materials have differing surface emissivities, which will produce
variations in the temperature readings. Variations can also be caused by the
distance from the object. This temperature measurement must be regarded as
an indication and not a guaranteed reading.
If the temperature falls outside the maximum value, the display will show "+++".
TM
SceneSave
Up to 100 images can be captured and stored in the Argus
These images can then be viewed or deleted using the remote
control or software provided. See section 2 for details of remote
control. Using the software provided, captured images can be
downloaded to a suitable laptop/PC in several formats.
To capture an image, press the left-hand button. The image capture symbol
appears for a short time above the ambient temperature reading and the
number of the image out of 100 will also be indicated on the display.
If the image capture button is pressed and the camera already has 100 images
stored, a 'CAMERA FULL' warning will appear. Before further images can be
captured, unwanted images will need to be deleted using the remote control or
software.
© e2v technologies (uk) limited
The Argus
average temperature of the centre spot of the
scene (defined by the target markings). The
Image Capture
TM
4 allows the operator to view the
104077
DAS709758AA (UK) version 7, page 7
TM
4.