Note: If the battery temperature is too low (<0 °C, 32 °F) or too high (>40 °C,
104 °F) for charging, the LED will show green while flashing yellow. This will
continue until the correct operating temperature has been reached.
If the battery temperature exceeds 60 °C (140 °F), the LED will flash
between orange and green. The charger will stop charging and the battery
will have to be removed from the charging shoe and the charger will have to
be reset by disconnection from the mains.
Once the battery has reached full charge, the charger will go into top-up charge
mode and the LED will turn green and flash intermittently yellow. Once the top-up
has been completed, the charger will go into maintenance mode and the LED will
show green.
It is recommended that the battery be removed from the charging shoe once
charged. Before fitting another battery into the charger, allow at least 30 seconds so
the battery charger can reset; the LED turning to yellow indicates that the charger
has reset.
LED COLOURS DURING NORMAL OPERATION
LED
Orange
Yellow
Yellow
Orange
Green with intermittent yellow flash
Green
LED COLOURS DURING FAULT CONDITIONS
LED
Green while flashing yellow
Flashing between orange and green
Note: On some models the "orange" LED may appear to have a red tint. This is
normal.
© e2v technologies (uk) limited
MODE
No battery fitted, initial power applied
No battery fitted, charger ready for use
Battery fitted, start-up trickle charging
Battery fitted, fast charging
Top-up charge
Charge complete, maintenance mode
MODE
Battery or charger out of operating
range.
Battery or charger has a fault. Remove
battery and disconnect the power.