Télécharger Imprimer la page

e2v Argus 4 Manuel D'utilisation page 20

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 24
Optical Data
Detector
Sensor material -
Spectral response -
MDTD (Minimum Discernible
Temperature Difference) -
Dynamic range -
Spot temperature range -
Ambient temperature range -
Lens
Horizontal aperture -
Viewing
Mechanical Data
Overall dimensions (H x W x D) -
including handle (H x W x D) -
Weight
with battery and handle -
Materials
Outer camera case
Electrical Data
Power Supply
© e2v technologies (uk) limited
Sensor type -
Resolution -
Refresh rate -
Lens material -
Focal length -
Focal distance -
Field of view -
Display type -
Display size -
Backlight -
without battery -
with battery -
-
Rear bumper -
Front bumper -
Neck strap -
Side straps -
Handle -
Power consumption -
Start-up time -
Uncooled Microbolometer
Amorphous Silicon (ASi)
160 x 120
8 – 14 μm
< 0.1 °C
P7130: -40 °C to 1000 °C (-40 °F to 1832 °F)
P7030: -40 °C to 800 °C (-40 °F to 1472 °F)
using 3 ranges with auto-switching between
ranges.
60 Hz (P7130); 30 Hz (P7030); 9 Hz (P7009)
-40 °C to 800 °C (-40 °F to 1472 °F)
-15 °C to 150 °C (5 °F to 302 °F)
Germanium
6 mm; 8.6 mm (P7130)
1 m to infinity, optimised at 4 m
(3 feet to infinity, optimised at 13 feet)
f/1.0
50° horizontal
Transflective, active matrix colour TFT
90 mm (3.5 inches)
White LED
130 mm x 185 mm x 185 mm
(5.1 x 7.2 x 7.2 inch) (nominal)
295 mm x 185 mm x 185 mm
(11.5 x 7.2 x 7.2 inch) (nominal)
< 1.2 kg (2.6 pounds)
< 1.5 kg (3.3 pounds)
< 1.7 kg (3.7 pounds)
®
Radel
R-5100
®
Multiflex
®
Multiflex
®
Nomex
®
Nomex
®
Radel
R-5100 overmoulded in Santoprene
3 W typical
5 seconds typical
104077
DAS709758AA (UK) version 7, page 19
®