Electrical Connections; Loose/Broken Cable Switch; Commissioning The Platform - ATT COMBI LIFT 4.50 S Manuel D'exploitation

Table des Matières

Publicité

The following preparation and work steps are to be
done:
• To achieve a greater degree of protection
against humidity from the workshop floor, a thin
PE foil should be placed between the workshop
floor and column base plate (3) before anchors
are placed. Also, the gap between the base
plate and workshop floor should be silicone spra-
yed after anchoring.
• Place the drive-in rails at the intended set up loca-
tion each with two assembly stands. Ensure precise
separation of the drive-in rails (see data sheet).
• Position each cross-beam at the front side of the
rails. Place the cables into proper position and
pull through the cross-beams. During this, check
the position of the cables to the cable rollers. Ca-
bles may not cross each other.
• Fasten cross-beams onto the rails, connect elec-
trical plugs.
• Position lift columns at the end of the cross-beams.
• Pull the cable through the ends of the cross-be-
ams and upwards to fasten on the head plate of
the lift column.
• Measure the position of the lift columns and align
with a bubble level.
• Holes for floor anchoring are to be made through
the 4 holes in the base plates (3).
• Clean the bore holes by blowing them out with
air. Insert safety anchors into the holes (also see
8.4 Selecting anchor).
1
2
3
4
1 grub screw
3 base
2 hexagon nut
4 pressure plate
• Before anchoring the lift, check whether the con-
crete is of quality C20/25 up to the finishing level
of the completed floor. In this case, take the an-
chor length from the anchor manufacturer's data
sheet. If there is a floor covering (tiles, screed)
on the weight bearing concrete, the thickness
of this covering must be determined. After-
wards, take the anchor length from the anchor
manufacturer's data sheet.
• Below the base plates (3) there are the installation
plates (4) on which the column by means of set
screws (1) and hexagonal nuts (2) can be set and
leveled.
• Tighten the anchors using a torque wrench.
182
• Tighten anchors with the curved washer to the
8.7
• Provide an on-site electrical connection of 3 ~/N
• Have an electrician connect the electric cable
8.8
002
5 Rope slack/rope break switch 7 rope holder
6 movable release element
8.9
• Tighten screws on the beams.
• Refill hydraulic oil The total oil volume of the oil
• Lift the platform slightly by pushing the "LIFT"
• Remove assembly stands and place the platform
OPI_COMBI LIFT 4.50/4.65 S PLUS AMS - HYMAX II 4500/4650 S PLUS AMS_V1.1_DE-EN-FR-ES-IT
Each anchor must be able to be tigh-
tened to the torque specified by the
manufacturer. Safe operation of the lift
is not guaranteed with a lower torque.
required torque, until the washer is laying flat
against the base plate (3). This ensures a secure
anchor connection.

Electrical connections

+ PE, 400 V, 50 Hz, fuses with 16 A, slow-blow (also
see Section 15 Electrical circuit diagram).
to the customer-provided mains breaker (e.g. a
Cekon plug).

Loose/broken cable switch

The loose/broken cable switch (5) is
only pre-mounted at the factory! After
threading in and fastening the cable,
the switch must be set according to
picture 004. This is required again after
each cable change or after the plat-
form has been moved.
Maximal
secured with
40 mm
2 nuts

Commissioning the platform

tank is approx. 13 litres.
button
o
(12) and at the same time pushing the
"bridge" button (16).
into the safety ratchets.
003
5
7
6
Minimal
15 mm
004

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Combi lift 4.50 s amsCombi lift 4.50 s plusCombi lift 4.50 s plus amsHymax ii 5000 sHymax ii 5000 s amsHymax ii 5000 s plus ... Afficher tout

Table des Matières