Rfh Rail Height Equalisation; 5.10 Safety Switch Below The Drive Rails; Behavior In Cases Of Error - ATT COMBI LIFT 4.50 S Manuel D'exploitation

Table des Matières

Publicité

• Push the "LOWER" button
wering process.
• The 4 safety ratchets are pulled back electrically
and after approx. 1.5 sec, the lift starts to lower.
• An acoustic warning signal sounds during lowe-
ring until the floor is reached.
• Once the lift is at the lowest position, the vehicle
can be driven off the lift.
5.9

RFH rail height equalisation

Longer continuous operation of the wheel free lift
without ever reaching the lowest position can result
in asynchronous running of the drive in rails. In nor-
mal cases height equalisation resets after a longer
waiting time (cooling of the oil).
For a residual height difference proceed as follows:
• At the wheel free lift, move the RFH switch (14) to
"I".
• Push the "LOWER" button
both rails of the wheel free lift have reached the
lowest position.
• Wheel free lift is functioning normally.

5.10 Safety switch below the drive rails

The lift has a safety switch (4) fitted below the drive-
in rails used to monitor the cables. This triggers if,
• a cable breaks
• the lift moves onto an obstacle and the cable
loosens
• only one safety ratchet has a catch latched in
and the cable is loose.
The lift then remains in place with no functionality.
i
6

Behavior in cases of error

Defective operational readiness of the system may
be due to a simple error. Check the system for the
listed sources of error.
If the error cannot be removed after an inspection
to the named causes, then inform customer service
or your dealer.
Independent repair work on safety
devices of the lift and checking the
electrical system may only be done
by specialists.
Problem: The lift cannot be raised
Possible causes:
No power supply
Only 2 phases active
OPI_COMBI LIFT 4.50/4.65 S PLUS AMS - HYMAX II 4500/4650 S PLUS AMS_V1.1_DE-EN-FR-ES-IT
(13) to restart the lo-
u
(13) and hold it until
u
Remedy:
Check the power supply
Do an on-site check with
a qualified electrician
The main switch is not
switched on, or is de-
fective
Defective fuse
"LIFT" button
o
defec-
tive
Motor has overheated
Motor defective
Insufficient hydraulic oil
available
Cable broken, safety
switch is activated
Problem: Motor starts, load is not lifted
Possible causes:
The vehicle is too heavy Unload vehicle if possible
Hydraulic oil filling level
is too low
Emergency discharge
screw is not closed
Emergency discharge
screw is not closed
Pressure lines blocked
Leak in the hydraulic
system
Problem: The lift cannot be lowered
Possible causes:
Lifting table is sitting on
an obstacle
Push the "Bridge" (16)
and "LIFT" buttons
o
(12)
Check the main switch
Check fuses
Check function
Inform customer service
Let the water cool (Coo-
ling time depends on
ambient temperature)
Do an emergency
discharge (see Section
6.2)
Inform customer service
Refill new hydraulic oil
Stop lift, inform customer
service
Remedy:
Refill new hydraulic oil
Close emergency
discharge screw
Check the valve
Inform customer service
Inform customer service
Remedy:
Raise the lift and remove
the obstacle.
Kundendienst benach-
richtigen
175

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Combi lift 4.50 s amsCombi lift 4.50 s plusCombi lift 4.50 s plus amsHymax ii 5000 sHymax ii 5000 s amsHymax ii 5000 s plus ... Afficher tout

Table des Matières