WIRING OF THE TORCH
Pin
Name
1
Phase 3
2
Phase 2
3
Phase 1
GND
4
5
5Vdc
HALL_A
6
HALL_B
7
HALL_C
8
GND
9
10
5Vdc
11
A
12
B
GND
13
14
24Vdc
Collision signal
15
Reverse signal Wire
16
Advance signal Wire
17
Signal EV GAZ
18
GND
19
20
10Vdc
21
IN 4
22
Detect_PP
Type_Mot
23
Signal EV AIR
24
DETERMINING THE FEEDER NUMBER
SMARTFEED wire feeders can be configured in «MASTER» or «SLAVE» mode.
In the case of two feeders, feeder no. 1 will be «MASTER» and feeder no. 2 will be «SLAVE».
The configuration is done via a DIP SWITCH (requires opening the product, see page 61-62).
ON
Master
1 2
1 2
If the configuration is not followed, the display of the HMI will show the
following error.
SMARTFEED M-4 / MB-PP
BRUSHLESS
Phase 3 - W
(motor supply)
(motor supply)
Phase 2 - V
(motor supply)
Phase 1 - U
Hall Effect Sensor
Encoder
500pts
Collision sensor
Dry contact between 24vdc and collision signal
Dry contact between GND and Reverse wire signal
Dry contact between GND and wire feed signal
Dry contact between GND and EV GAZ signal
Torch selection
Dry contact between GND and EV AIR signal
ON
Slave
Function
DC
(-) Motor
(motor supply)
(+) Motor
(motor supply)
HARDWARE error
NODE : MMI
CODE : 0000
...
EN
15