TROUBLESHOOTING
Covered
Mode
CO
10°C ≤ t°< 20°C
T° water
or covered pool
Treatment
2h
time
Filtration
5h to 10h
time
If despite this you encounter problems then, maybe your electrolyzer is down. Also, the
electrolyzer has a self-diagnostic system to indicate a possible problem via error codes.
Special case: hard water
In areas where the water is very hard (= high calcium content) and in pools with an unbalanced
chemical composition, the cell may require specific cleaning. Indeed, electrolysis creates
chlorine (hypochlorite) from salt but also naturally generates the formation of a mineral deposit
on titanium electrodes in the cell. The self-cleaning function by polarity inversion helps to
prevent the formation of these deposits and scaling. If the water is very hard and the TH is
high, the formation of deposits is inevitable and these must be removed.
Replacing the cell
Once the titanium plates inside the chlorinator cell have reached the end of their service life
(after around 10,000h), they can be replaced. To guarantee quality and value, only use original
spare parts. If necessary, bypass tubes can be used to allow water to continue circulating in
the pipework once the cell has been removed. See chapter on winterizing (Winterizing tube
product ref. CL-TSLTUBE).
List of error codes and their solutions
E2
: Water temperature is outside of normal operating range
Comment : The normal operating range for water temperature is between 10°C and 45°C.
Solution : Check the water temperature
• If the water temperature of your pool is below 10°C, consider winterizing your device.
• If the water temperature of your pool is above 45°C, switch off the chlorinator and wait for
the temperature to drop to the normal operating range.
• If the actual temperature of the water is within the normal operating range, check if error
code E3 or E7 is also displayed (see section on errors E3 and E7 below).
Spring
Summer
P4
P6
20°C≤t°< 25°C 25°C ≤ t°< 28°C
4h
6h
10h to 12h
12h to 16h
Comfort
BOOST 1
P8
B1
t° ≥ 28°C or
t° ≥ 28°C
intensive use
8h
12h
16h to 24h
24h
BOOST 2
B2
t° ≥ 30°C or
intensive use
24h
24h