If the memorisation has been successful, the LED L2 will emit a long flash
5
To memorize another remote control on the same output, repeat point 3
Note After 7 seconds of inactivity, the receiver automatically exits the programming phase
PHASE DESCRIPTION
1
Press the RADIO button until the LED L2 lights up (about 3 seconds)
Within 7 seconds, press and hold a button of the remote control that you wish to delete until the LED
2
L2 on the receiver goes off. Release the remote control button
3
After about 1 second from releasing the button the LED L2 on the receiver starts to flash
4
Confirm deleting by pressing the RADIO button
5
If deleting has been successful, the LED L2 will emit one long flash
Note After 7 seconds of inactivity, the receiver automatically exits the deleting phase
MANUAL CLEARING THE ENTIRE RECEIVER MEMORY/RECEIVER RESET
PHASE DESCRIPTION
Press and hold the RADIO button until the LED L2 lights up (about 3 seconds) and then goes off
1
(about 3 seconds). Release the button
2
After about 1 second from releasing the button the LED L2 on the receiver starts to flash
3
To delete all the memory, press the RADIO button upon the third flash
4
If deleting/resetting has been successful the LED L2 will emit one long flash
MANUAL REMOTE MEMORISATION OF A REMOTE CONTROL WITH A REMOTE CONTROL ALREADY MEMORISED
A transmitter can be memorised without accessing the re-
ceiver. The user needs to have a transmitter memorised pre-
viously, after which the procedure is as described below. The
PHASE DESCRIPTION
1
Press and hold the button of the new radio control that you wish to store for at least 5 seconds
Press and hold the button of the old radio control to be copied for at least 3 seconds (if the previous
2
phase 1 was successful, the automation system will not move)
3
Press and hold the button of the new remote control that you wish to store for at least 3 seconds
Press and hold the button of the old remote control to be copied for at least 3 seconds to confirm
4
and exit the programming phase
Note After 7 seconds of inactivity, the receiver automatically exits the programming phase

4.13 - Manual learning opening and closing values

ATTENTION !
If you had previously connected the SMART module, power
the device off for a few seconds to be able to use the manual
procedure.
The photocell contact must be connected to the COM and PH
terminals. To bypass the photocell, move the left-hand dip
switch upwards. After having activated the dip switch, the
LEDs L1 and L2 start to flash at a fast rate.
ATTENTION !
Confirm input ph deactivation by pressing the menu and radio
buttons simultaneously and holding them down until the leds
L1 and L2 stop flashing.
MANUAL DELETING A REMOTE CONTROL
remote copy procedure must be carried out in the area served
by the receiver.
The inputs of the sensitive EDGE must be connected to the EDGE
and EDGE terminals. To bypass the sensitive edge, move the
right-hand dip switch upwards. After having activated the dip
switch, the LEDs L1 and L2 start to flash at a fast rate.
Confirm input edge deactivation by pressing the menu and
radio buttons simultaneously and holding them down until
the leds L1 and L2 stop flashing.
Note: Led intensity will descrease during movement of the door
Otherwise proceed as described below:
ATTENTION !
EN
>3s
EXAMPLE
>3s ►
0,5s
0,5s
>3s
EXAMPLE
>3s ►
>3s ►
1s ►
1s ►
EXAMPLE
>5s
>3s
>3s
>3s