2.4 - Technical specifications

Recommended model and use - Available rails and dimensions
MODEL
MATERIAL
RAIL-CLED
Aluminium
RAIL-CLED4
Aluminium
RAIL-C3x1
Steel
RAIL-C3
Steel
RAIL-C4
Steel
The data shown may vary according to the sliding and balancing performance of the door and the type of rail used.
330
RAIL-CLED
RAIL-CLED4
P MAX = 84
330
RAIL-C3x1
RAIL-C3
RAIL-C4
P MAX = 84

2.5 - List of cables required

In a typical plant, the cables necessary for connection of the various
devices are shown in the cable list table. The cables used must be
suitable for the type of installation, for example we recommend a
CABLE LIST
CONNECTION
Power supply line
Flashing light, courtesy light
Antenna
Transmitter photocells
Receiver photocells
Radio sensitive edge (*)
Key selector
Demander à un personnel qualifié de procéder à l'installation d'une
prise adaptée si aucune n'a été prévue à proximité des machines.

3 - PRELIMINARY CHECKS

Before installing the product, check and verify the following points:
- Check that the door is suitable for automated control
- The weight and the size of the door must be within the limits of
use specified for the automation system in which the product is
integrated
- Check that the mechanical safety stops required on the door are
solid and properly installed
- Check that the product fixing area is not subject to flooding
- Heavy acidity or salinity conditions or proximity to sources of heat
may cause product malfunction
- In case of extreme weather conditions (for example snow, ice,
sudden temperature changes, high temperatures) friction could
increase and consequently, the force necessary for movement and
initial start-up could be higher than that required under standard
NOTES
With integrated LED lighting
With integrated LED lighting
3065 / 4065
114
mm
3075 / 4075
70,5
mm
DRIVE TYPE
TOTAL LENGTH RAIL TRAVEL
Belt
3090 mm (1x3m)
4090 mm (1x4m)
Belt
3100 mm (3x1.03m) 2670 mm
Belt
Belt
3100 mm (1x3.1m)
Belt
4100 mm (1x4.1m)
H03VV-F type cable for indoor installation or H07RN-F for outdoor
installation.
CABLE TYPE
Schuko CEE 7/4
1 x cable 3 x 0,5 mm
2
1 x RG58 type cable
1 x cable 2 x 0,5 mm
2
1 x cable 4 x 0,5 mm
2
1 x cable 4 x 0,5 mm
2
1 x cable 2 x 0,5 mm
2
(*) : se reporter aux instructions du producteur
conditions
- Check that the manual movement of the door is smooth and free
from peak friction points and that there is no risk of the door going
off its rails
- Check that the door is well balanced and will not move
notwithstanding the position it is left in
- Check that the power line to which the product is to be connected
is equipped with an adequate safety earthing system and protected
by a magnetothermic circuit breaker and differential cutoff device
- Provide a disconnecting device in the system power supply network
with a contact opening gap that allows for complete disconnection in
the conditions provided by the overvoltage category III.
- Check that all the material used for installation complies with the
regulations in force
2660 mm
3660 mm
2670 mm
3670 mm
MAX LENGTH PERMITTED
20 m
20 m (recommended < 5 m)
20 m
20 m
<2 m
20 m