1/2 IN. DR MAINTENANCE FREE AIR IMPACT WRENCH
TROUBLESHOOTING
Visit a Princess Auto Ltd. location for a solution if the tool does
not function properly or parts are missing. If unable to do so,
have a qualified technician service the tool.
PROBLEM(S)
Tool runs at
normal speed,
but loses power
under load.
Tool runs
slowly. Air flows
slightly from
exhaust.
Tools will not
run. Air flows
freely from
exhaust.
Tool will not
shut off.
12
POSSIBLE CAUSE(S) SUGGESTED SOLUTION(S)
Motor parts worn.
1. Motor parts
jammed with dirt
particles or
airflow blocked
by dirt.
2. Air regulator in
closed position.
Damage or
excessive wearing of
internal parts.
1. Throttle valve
o-ring dislodged
from seat inlet
valve.
2. Trigger
mechanism
jammed or dirty.
For technical questions call 1-800-665-8685
1. Have a qualified technician
service the tool.
2. Replace tool or parts.
1. Check air inlet filter for
blockage.
1.1 Pour air tool lubricating
oil into air inlet as per
lubrication instructions
for clearing shipping
grease.
1.2 Operate tool in short
bursts to clear debris.
1.3 If tool still jammed,
clean tool and lubricate
per lubrication
instructions.
2. Open the air regulator to
desired airflow.
1. Have a qualified technician
service the tool.
2. Replace tool or parts.
1. Replace throttle valve
o-rings.
2. Clean trigger mechanism
and lubricate.