Electric Motor
Type
Voltage
Power output
RPM, max. load
Current
Efficiency
Duty cycle
6
Protection
Direction of rotation
Chopper frequency
Charging current, while
acting as generator:
Protection
Main current
Control current
Excess temperature
Motor installation
Max. installation angle
Max. rearward angle
8
: Reversible
brushless DC motor
: 24 V Direct Current
: 2200 W
: 1200 RPM
: 120 A at 2200 W / 1200 RPM
10 A at 2200 W / 960 RPM
: 76% at max. power and 1200 RPM
71% at max. power and 960 RPM
: 100%
: IP20
: Clockwise, when moving forward.
: 12,000 Hz.
Max. 50 A (only EP2200H)
: 160 Amp 'Slow-blow' fuse
(ZE160).
: Glass fuse 1 Amp 'Fast'
: 10% reduction per deg. C over
80 deg. C (176 °F)
: No restriction
: No restriction
Cooling System
Circulation pump,
Capacity
Pump RPM
Max.pump head
Impeller
V-belt
Cooling water temperature : 0 to + 2 degrees C
Ambient temperature
During storage
During use
Weight
This product conforms to the EEC Guideline requirements:
• EN50081-1 and EN50082-2 (EMC)
• DIN/IEC 68-2-6 and DIN/IEC 68-2-29 (Vibration)

Technical Data

: 10 litres/min ( 2.2 gal UK per min)
at 1200 motor RPM
8 litres/min (1.75 gal UK per min)
at 960 motor RPM
: 1.25 x motor RPM
: 5 m water (200 in H2O)
: STM7180 (Vetus part)
: STM7161 (Vetus part)
(+ 2 to + 90 degrees F)
: — 20 to + 40 degrees C
(— 4 to + 104 degrees F)
: 0 to + 40 degrees C
(+ 2 to + 104 degrees F)
: 0 kg (66 lbs)