8.4 Set to the full vessel
► Fill the vessel/pipe�
> The probe tip must be completely covered with the medium�
► Execute the system command [tSP1] or [tSP2]�
> The unit automatically sets the switching thresholds [SPx]/[rPx]�
► Check the function by an application test�

9 Operation

When the supply voltage has been applied, the unit is in the operating mode� It
carries out its evaluation functions and switches the outputs�
► Check whether the unit operates correctly�
Table 9-1 indicates the factory settings� In this state:
OUT1 = Hno and OUT2 = Hnc�
Operating mode
Unit ready for operation, no medium
detected
Unit ready for operation, medium detected
No operating voltage
Short circuit output 1
Short circuit output 2
Error / failure
) According to the level
1
The LEDs always indicate the switching status of output OUT1�

10 Maintenance, repair, disposal

► From time to time check the probe tip for deposits and damage� Clean the unit
if badly soiled� In case of damage replace the unit�
When the medium is changed, it may also be necessary to use another
type of unit or adapt the sensitivity�
32