4�3�2 Application Examples For Rear Installation Via Pipe - Autosen AF005 Notice D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

4.3.2 Application examples for rear installation via pipe
Installation from the top:
1: Maximum level
Rear installation of the sensor in a pipe of variable length (3) is possible� Different
response points can be implemented�
Example: monitoring maximum level (1) or minimum level (2)�
► Use metal probes with G 1/2 internal thread and internal diameter of
min� 19 mm�
If the sensor is permanently covered by the medium:
► The temperature in the pipe must not exceed the max� ambient tempe-
rature due to a too high medium temperature. (→ Technical data sheet).
24
2: Minimum level
3: Probe