Display control

10. Display control
These units incorporate a display and keypad unit to interface with the installer
and the user.
This interface allows the display of the main internal parameters and the
configuration of the entire system during installation.
Parameters, variables and commands are organised as menus and submenus.

10.1. Keypad and LEDs

The keypad has four keys:
To exit a parameter, leave a menu and return to the next level up in the structure to not confirm a
change or not accept a suggestion.
With this key you can scroll up the list of parameters or folders within the same level or increase
the value of an editable parameter by one base unit.
Scroll down the list of parameters or folders within the same level or decrease the value of an
editable parameter by one base unit.
Its purpose is to accept a parameter as valid, to enter a lower level menu in the structure, to
confirm a change or accept a suggestion.
The panel consists of three LEDs, green orange and red:
Green LED
Off: inverter disconnected.
On: inverter connected to the grid.
Flashes once: the conditions are not valid for feeding the grid (low Vdc voltage or
other alarm).
Flashes six times: the connection conditions are valid. The inverter is in the process
of connecting to the grid.
Orange LED
Consult section "15. Troubleshooting".
Red LED
Consult section "15. Troubleshooting".