15.2. Low-water display (PRO C3 only)

The sauna control unit features an automatic low-water cut-out feature which is
active in combi mode, as long as your combi heater supports it.
If the water tank in the vaporizer is empty, this is indicated by a recurring warn-
ing tone and the text "FILL" appears in the additional display 1. The vaporizer
switches off at the same time.
● Pour water into the water tank in the vaporizer.
► After a short period, the text "FILL" goes out and the vaporizer starts
heating up again.

15.3. Fuses

Fuses for light, fan/power expansion and electronics as well as a spare fuse are
located in the sauna control unit's connection area.
These are 1A time delay micro fuses.
They can be ordered using the item number PRO-FUSE.
EN
Light
Electronics
Fan/power expansion
Spare fuse
In order to replace the fuse, pull the fuse link straight out and insert the new fuse.