BFT LIBRA-C-LX Instructions D'installation page 13

Centrale de commande
Masquer les pouces Voir aussi pour LIBRA-C-LX:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 19
Press the OK key
Control unit software version
N. total manoeuvres (x 100)
N. manoeuvres since latest maintenance (x 100)
N. radio control devices memorised
- +
- +
- +
- +
LIMIT SWITCH ADJUSTMENT
ACCESS TO MENUS Fig. 1
+/-
OK
OK
DIAGNOSTICS
OK
OK
OK
OK
* X = 0,1,...,9,A,B,C,D,E,F
See PARAMETERS MENU
See LOGIC MENU
See RADIO MENU
OK
OK
DIAGNOSTICS and WARNINGS
DESCRIPTION
CODE
photocell test anomaly
Er01
safety edge test anomaly
Er02
photocell test anomaly
Er03
during opening
photocell test anomaly
Er04
during closing
Er1X *
hardware anomaly
Er2X *
encoder anomaly
Er3X *
amperostop anomaly
Er4X *
thermal cutout anomaly
Er5X *
communication anomaly
no-power anomaly
Er60
(restart)
buffer battery power
Er61
anomaly
power out-of-range
Er62
anomaly
Scroll up
Scroll down
Confirm/Switch on display
Exit Menù
NOTES
check photocell connection and/or pa-
rameter/logic settings
check safety edge connection and/or pa-
rameter/logic settings
check photocell connection during OP
and/or parameter/logic settings
check photocell connection during CL
and/or parameter/logic settings
check connections to motor
motor is moved manually and/or check
encoder and relevant wiring
make sure movement is not hindered
allow automated device to cool
check connection with accessory devices
and/or expansion boards or serial-con-
nected devices
there was a power loss. Board is now ac-
tive again
automated device running on battery
power
supply voltage not in 230V+/-10% range
LIBRA-C-LX - 13

Publicité

Table des Matières
loading