In accordance with the previous diagram, for correct operation, the cable sections should be suitable to the length of
the cable. The sections and lengths for a line in which there is only one modulator, without any projector, are given
below:
For a line in which there are projectors, the sections are lengths are:
1 projector in the line
L.Projector (m)
55 – 90
35 – 55
20 – 35
14 – 20
0 – 14
2 projectors in the line
L.Projector (m)
25 – 45
18 - 25
10 - 18
7 - 10
0 - 7
A modulator and projectors can be in the same
line.
Do not install the 12V~AC power lines of the
lamps and modulators near possible electrical
interference of other signals.
4. ASSEMBLY:
Follow these steps to assemble the PAR56 led lamp in an underwater projector with an incandescent lamp:
1. Ensure that the lamp is NOT receiving voltage.
2. Remove the lamp unit and the part of the projector and place it on the edge of the swimming pool (this operation
is fully described in the projector manual).
Modulator Line (m)
150 - 300
0 - 150
Section
10mm² Cu
6mm² Cu
4mm² Cu
2,5mm² Cu
1,5mm² Cu
Section
10mm² Cu
6mm² Cu
4mm² Cu
2,5mm² Cu
1,5mm² Cu
Section
2,5mm² Cu
1,5mm² Cu
5 projectors in the line
L.Projector (m)
10 - 18
7 - 10
4 - 7
0 - 4
10 projectors in the line
L.Projector (m)
0 - 9
3
Section
10mm² Cu
6mm² Cu
4mm² Cu
2,5mm² Cu
Section
10mm² Cu