MAIN COMPONENTS

1
Front panel
2
Horizontal air supply deflector
3
Vertical air supply deflector
4
Air filter
5
Heat exchanger coil
Colour
Pantone code: GRIS 1C
RAL code: 9010
1

DESCRIPTION OF THE COMPONENTS

FRONT PANEL
The air is taken in via the louvers. By raising the panel,
you can access the air filters and other internal parts.
RECEIVER
Infrared signal receiver in versions with microprocessor
control with electronic board.
DISPLAY
The display is located on the front panel in versions with
microprocessor control with electronic board. It shows
the ventilation speed, operating mode, temperature,
error messages and timer.
AIR FILTER
Regenerable air filters that are easy to take out for
cleaning.
HEAT EXCHANGER COIL
Made of a copper tube with turbo aluminium fins.
AIR SUPPLY
The horizontal deflector is motorised.
The vertical fins can be manually orientated to direct the
air flow as needed.
AUXILIARY EMERGENCY SWITCH
The auxiliary emergency switch is used to activate
or deactivate the fan coil if the remote control isn't
working.
FAN UNIT
The fan unit is fitted with an extremely compact and quiet
tangential fan.
2-way WATER VALVE
The FCWI_2V fan coil is fitted as standard with a
2-way water valve of the all-or-nothing type, with an
electrothermal actuator controlled by the fan coil board
on the basis of the water temperature and the room
temperature.
2
3
5
4
6
Auxiliary emergency switch
7
Control board for electrical connections
8
Front element
9
Frame
10 Display
FCWI
10
3
6
7
TLW3
PFW3
PFW2
3-way WATER VALVE
The FCWI_3V fan coil is fitted as standard with a
3-way water valve of the all-or-nothing type, with an
electrothermal actuator controlled by the fan coil board
on the basis of the water temperature and the room
temperature.
TLW3 REMOTE CONTROL (accessory for FCWI) - this
accessory is essential for fan coil operation (as an
alternative to PFW3)
The TLW3 remote control is supplied separately from the
fan coil. A single remote control can command several
fan coils.
The remote control allows you to set all the device
operating parameters, which are shown on a liquid
crystal display to facilitate programming.
The remote control has a support so it can be hung on the
wall.
PFW3 WIRED PANEL (accessory for FCWI)
This accessory is essential for fan coil operation (as an
alternative to TLW3)
The PFW3 wired panel is supplied separately from the
fan coil. It is used to set the main device operating
parameters, and is essential for setting the Modbus
address of the unit (handy only if you want to command
the unit via the RS-485 port).
9
8
27