Remote Sensor Specifications; Detection Ranges And Alarm Levels - Honeywell E3 Point Manuel D'utilisation

Masquer les pouces Voir aussi pour E3 Point:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Specifications

Remote Sensor Specifications

Power:
Operating temperature:
Operating humidity:
Sensor type:
Visual indicator:
Size (DxWxH):
Weight:

Detection Ranges and Alarm Levels

Gas Detected
CO
Carbon monoxide
H
S
Hydrogen sulfide
2
NO
Nitrogen dioxide
2
O
Oxygen
2
COMB
Combustibles
Maximum Overload is the sensor exposure to gas concentration that
may result in permanent damage to the sensor.
34
Electrochemical sensor: 10-24 VDC, 50 mA
Catalytic: 10-16 VDC, 100 mA
-20 to 50°C (-4 to 122°F)
15 to 90% relative humidity (non-condensing)
Electrochemical cell (CO, NO
(Comb)
Amber LED (Tx)
3.5 x 4.5 x 6.5 cm (1.36 x 1.75 x 2.56 in.)
38 g (1.34 oz.)
Range
Alarm A
0-250 ppm
25 ppm
0-50 ppm
10 ppm
0-10 ppm
0.7 ppm
0-25 %vol
19.5 %vol.
0-100 %LEL
25 %LEL
, H
S, O
2
2
Alarm B
Alarm C
100 ppm
225 ppm
15 ppm
20 ppm
2 ppm
9 ppm
22 %vol.
22.5 %vol
50 %LEL
90 %LEL
E
Point Standalone Gas Monitor User Manual
3
); catalytic
2
Maximum
Overload
500 ppm
150 ppm
1000 ppm
100 %vol
100 %LEL

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

E3point

Table des Matières