The scanner and control panel must be connected with a four-wire cable with a mini-
mum diameter of 0.5 mm (corresponding to a single wire cross-section of 0.2mm²).
The use of a CAT5 cable is recommended by ekey biometric systems for reasons of availa-
bility. Distances exceeding 50m require electrical cables with a larger wire cross-section for
connections 3 and 4.
There is one relay (three relays for the ekey
control of external devices. The programming menu is used for programming.
The relay is equipped with a change-over contact that can be used at your own discretion
and has a maximum switching capacity of 250VAC 5A. Each door lock, without exception,
must be connected to a separate power supply. (Do not use the provided energy supply
plug.)
The cable between the scanner and control panels must be connected separately from the
electrical house installation because of signals in the low voltage range that can be inter-
rupted by neighbouring current-carrying cables.
The connections are not reverse-battery-protected.
ATTENTION:
The electrical unit should be installed by a professional technician.
Communication between the scanner and control panels is by means of connections 1 and 2.
The power supply for the scanner and control panels is by means of connections 3 and 4.
4. OPERATION

4.1. USING THE OPERATION KEYS OF CONTROL PANEL

Programming is carried out via the 4 keys (see Figure 2):
-key:
OK=
< and > -keys:
-keys:
=
®
to enter the menu and to conirm your input.
to change the values in the display
and for navigating (refer to chapter 4.3).
to cancel the current selection.
TOCAhome 3 and pc options) available for
19