Indicators Message

The POWER indicator, LAMP indicator, and TEMP indicator are lit and blank as follows. Take the
appropriate measures.
Table 10. Indicators Message
POWER
LAMP
TEMP
indicator
indicator
indicator
Lights
Turns off Turns off
orange
Blinks
Turns off Turns off
green
Lights
Turns off Turns off
green
Blinks
Turns off Turns off
orange
Blinks red
-
Blinks
Lights
Turns off
/Lights red
red
Blinks
Blinks
Turns off
/Lights red
red
Blinks
Blinks
Turns off
/Lights red
red
Blinks
Turns off Lights red
/Lights red
Lights
Blinks
Blinks
green
red
red
NOTE
*2) When the internal temperature becomes excessive power is switched OFF
automatically for safety reasons, and the indicator is extinguished. Set the power switch to [O] and
wait for 20 minutes until the equipment has cooled sufficiently.
ENGLISH-20
S
H
O
O
T
I
N
S
H
O
O
T
I
N
The Standby mode has been set.
Warming up. Please wait.
ON. Normal operation possible.
Cooling. Please wait.
Cooling. Please wait.
-
The error is found. Take the appropriate measures when the
POWER indicator ceases blinking
Lamp is not lit.
The interior of the equipment may be too hot. Switch power OFF,
wait 20 minutes until the equipment cools, and check whether the
ventilation openings are blocked, whether the air filter is dirty, or
whether the ambient temperature exceeds 35 °C. And switch
power ON again. Replace the lamp if the same problem occurs.
Lamp or lamp cover is not found, or hasn't been fitted in correctly.
Switch power OFF, and wait for 45 minutes until the equipment
cools. Check fitting of the lamp and lamp cover, and switch power
ON again. Contact your dealer if the same problem occurs again.
The cooling fan is not operating.
Switch power OFF, and wait for 20 minutes until the equipment
cools. Check for foreign matters in the fan, and switch power ON
again. Contact your dealer if the same problem occurs again.
The interior of the equipment is too hot. *2)
Switch power OFF, and wait for 20 minutes until the equipment
cools. Check whether the ventilation openings are blocked,
whether the air filter is dirty, or whether the ambient temperature
exceeds 35 °C. Then switch power ON again. Contact your dealer if
the same problem occurs again.
The interior of the equipment is too cool.
Check whether the ambient temperature is below 0°C. Contact your
dealer if the same problem occurs when the ambient temperature is
0~35°C.