DNCI−...
If the cylinders are arranged parallel:
Take the following minimum space requirements into account: Otherwise the
S
magnetic fields of the two cylinders will influence each other and lead to evalu
ation faults in the measuring system.
Parallel arrangement
Bearing cover flush
No minimum distance
With direct fastening or if mounting accessories are used, in each case with
cylinder collar milling:
Select one of the fastening possibilities listed in the following table:
S
Double screwing with foot fastening
type HNA−... in the threaded holes of
the cover screws
Fig. 5
Festo DNCI−... 0610a English
Bearing cover offset (Y > 0)
Minimum distance X > 70 mm
Double screwing with foot fastening
type FNC−... in the threaded holes of
the cover screws
23