9.4.4 Changing the FEC filter pad
1
Housing
2
FEC filter pad
Fig. 15
Changing the FEC filter pad
1 Place a non-slip base (fleece, cardboard, blanket, or similar) on the floor. Ensure it is large enough for the area you want
to protect.
2 Place the device on the non-slip base and turn it onto its back.
3 Loosen the four mounting screws (4) with the Allen key.
4 Remove the cover grille (3).
5 Remove the FEC filter pad (2).
6 Insert the cleaned or new FEC filter pad (2).
7 Mount the cover grille (3).
8 Insert the four mounting screws (4).
9 Tighten the four mounting screws (4) with the Allen key.
10Bring the device into an upright position again.
11 Remove the non-slip base.
BAL.0533.0 • 2019-11-15
9 Maintenance and cleaning
3
Cover grille
4
Mounting screws (4 pcs.)
1
2
3
4