Les langues disponibles

9 Maintenance and cleaning
9.2 Filter dedusting
NOTICE
• Check and wear your personal protective equipment.
• Personal protective equipment consists of protective clothing, safety goggles, a class P3 respiratory mask, protective
gloves and safety shoes.
• Personal protective equipment must be worn when in the vicinity of the dust collecting bag as it is being filled with the
separated dust.
• The filter should be cleaned at least once per work shift, depending on how often the system is used.
• The filter must be cleaned immediately if the "Dirty" LED is illuminated on the control panel.
1
1
Valve lever
Fig. 10
Dedusting of the filter cartridge
NOTICE
• Use only dry and oil-free compressed air (min. 5 – max. 6,5 bar).
1 Connect the compressed air supply.
2 Open the valve lever (1) on the compressed air connector (2).
The compressed air creates a dedusting jet and causes the dedusting nozzle to rotate inside the filter cartridge.
3 Manually move the cleaning lance (3) up and down.
The filter cartridge (4) is cleaned by manually moving the cleaning lance (3) up and down.
4 Close the valve lever (1) on the compressed air connector (2).
5 After the system has been dedusted, disconnect the FEC from the compressed air connection.
6 Empty the separated dust from the filter housing in the supplied dust collecting bag.
 Fig. 11 Emptying the filter housing on page EN-19
EN - 18
2
2
Compressed air connection
for dedusting
3
4
3
Cleaning lance
4
BAL.0533.0 • 2019-11-15
FEC
Filter cartridge

Publicité