Working Advice - Bosch UniversalDetect Notice Originale

Masquer les pouces Voir aussi pour UniversalDetect:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 33
OBJ_BUCH-3069-001.book Page 27 Tuesday, April 18, 2017 2:39 PM

Working Advice

Marking Objects
If required, detected objects can be marked. Perform a measurement as usual. Once
you have found an object, mark its position through the marking hole 8.
The symbol shown on the measuring tool may change while you are making this mark
as the marking hole is directly in the sensor area 1 and the pen you use may disturb
the sensors.
Always start a new measurement after marking a position. You can do this by lifting
the measuring tool off the wall and then putting it down again. This will ensure that the
marking process does not affect the measuring results that follow.
Troubleshooting – Causes and Corrective Measures
Cause
"Metal" mode: Ring 7 lights up yellow or red even though there is no metal nearby
Ambient temperature is too
high/too low
Severe temperature change Wait until the measuring tool acclimates to the ambi-
Auto calibration not
successful
"Metal" mode: Ring 7 lights up yellow or red over a large measuring area
on the wall
Many, closely spaced metal
objects
Building materials containing
metal or reinforcing steel in
the concrete
Solid metal objects on the
back of the wall
Auto calibration not
successful
"Current" mode: Ring 7 lights up red over a large measuring area on the wall
Improper grounding of the
wall
Bosch Power Tools
Corrective Measure
Only use the measuring tool in an operating tempera-
ture range of –5 °C to +40 °C.
ent temperature.
Perform calibration manually (see "Reset", page 26).
Metal objects spaced too closely together cannot be
detected separately.
A reliable detection is not possible with metallic build-
ing materials (e.g. foil-laminated insulation materials,
heat sinks).
Detection will not be accurate in the presence of solid
metal objects (e.g. radiators).
Perform calibration manually (see "Reset", page 26).
With your free hand, touch the wall at a distance of
20–30 cm from the measuring tool to ground the wall.
English | 27