Installation and Operating Instructions
EN
Central ventilation unit – KWL 470 W/W ET
ⓘ The bypass must be activated for controlling the supply air temperature.
• Rel. humidity
ⓘ     S etting is adopted for internal and external sensor.
• CO2/VOC
ⓘ       S etting is adopted for CO2 and VOC sensor.
AWAY FROM HOME
Ventilation profile in the absence of persons.
The following parameters can be adjusted:
• Fan power
• Supply air
• Rel. humidity
ⓘ   S etting is adopted for internal and external sensor.
• CO2/VOC
ⓘ     S etting is adopted for CO2 and VOC sensor.
INTENSIVE VENTILATION
Ventilation profile in presence of several persons or if intensive ventilation is desired.
The following parameters can be adjusted:
• Fan power
• Supply air
• Rel. humidity
ⓘ   S etting is adopted for internal and external sensor.
• CO2/VOC
ⓘ     S etting is adopted for CO2 and VOC sensor.
• Duration
FIREPLACE MODE
Ventilation profile when using e.g. a chimney.
The following parameters can be adjusted:
• Supply air fan
• Extract air fan
• Duration
ⓘ A slight overpressure can be set for this ventilation profile to prevent smoke from entering the apartment. The
function does not replace an underpressure monitoring system!
8.2.2 Filter replacement
The following filter replacement information can be called up or adjusted using the pen
• Filter replaced
Displays the date of the last filter replacement.
ⓘ This date must be updated for each filter replacement to confirm the filter replacement.
• Next replacement
Displays the date of the next filter replacement.
• Replacement interval
Displays the interval for filter replacement. The interval for filter replacement can be adjusted between 1 and 12
months depending on the level of contamination.
ⓘ The filters must be replaced as required but at least 1x annually (factory setting: 6 months).
8.2.3 Temperatures
The current supply air, extract air, exhaust air and intake air temperatures are displayed.
8.2.4 Unit data
The following unit data is displayed:
• Ventilation
• Heat exchanger status
• Relative humidity
• CO2/VOC
8.2.5 Sensors
The connected sensor data is displayed.
8.2.6 Temperatures and sensors
Graphical representation of the temperatures and connected sensors.
ⓘ In order to retrieve the data, it must first be updated using the
ⓘ The temperatures and sensors can be selected or deselected by clicking on the corresponding legend.
ⓘ If multiple sensors are connected, the sensor data from the sensor with the highest value will always be taken
over.
23
:
button.

Publicité

loading

Ce manuel est également adapté pour:

Kwl 470 w et