Troubleshooting Guide - SciCan Aquastat W 10000 Guide D'utilisation Et D'entretien

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 15

Troubleshooting Guide

Problem
Start button does
not light up.
Start button lights up, but
fan does not start.
Distiller does not
operate.
Steam appears near
the top of the boiling
chamber.
Water leaks from top
of distiller.
The distiller shuts off
before the cycle is
complete.
Use and Care Guide
Possible cause
Distiller is not plugged in.
Boiling chamber is not
fully inserted.
The fan's delayed start
system has not activated.
Distiller is not plugged in.
Outlet is defective, or
fuse or circuit breaker
has tripped.
Electrical power has
been interrupted.
The baffle is missing or
is improperly installed.
Boiling chamber cap is
missing or loose.
The cap is on the
water bottle.
Loose baffle, missing
baffle, or baffle is not
secured properly in the
spout of the boiling
chamber.
Solution
Plug the distiller into a
rated voltage outlet.
Make sure the boiling
chamber is seated
properly. See #8 page 6.
Wait at least
1 ⁄ 2
hour for
the fan to start.
Plug the distiller into a
rated outlet.
Check fuses or circuit
breakers or call an
electrician.
Press start button
to restart. See #9 page 6.
Properly install the baffle.
See #6 page 5.
Securely install the
boiling chamber cap.
Remove the cap from the
water bottle during the
distillation cycle.
The screwed fitting can
become loose during
cycles. Assure that this
fitting is tightened before
each use. The baffle
must be installed
with the flat side down
(this means that the hole
is down) and the narrow
end inserted into the
spout of the boiling
chamber. See page 5.
9

Publicité

Table des Matières
loading

Produits Connexes pour SciCan Aquastat W 10000

Table des Matières