Télécharger Imprimer la page

GE UVC9480 Manuel Du Propriétaire Et Instructions D'installation page 20

Publicité

Les langues disponibles

Les langues disponibles

STEP 5 INSTALL BLOWER MOTOR ASSEMBLY - UVC 9420 AND 9480
METHOD 2 (ALTERNATIVE)
The motors can also be installed separately to help manage the weight of the 2 motors.
1. See see Remove Motor Assembly from Hood
Canopy section to disassemble the motor assembly
from the canopy.
2. With the motor assembly out of the canopy, remove
the 4 screws from each motor. The motors are
separate from the motor plate.
Motor
3. Mount the hood into the cabinet as shown in
previous instructions. Mount the motor plate,
inserting it in the hood slots. Slide it, making sure
the 4 tabs are engaged.
4. Reinstall the 4 screws removed earlier. See
Remove Motor Assembly from Hood Canopy
section. Make sure the plate is secured firmly to the
hood canopy.
20
Installation - UVC 9420 and 9480
Screws
Motor
Motor
Plate
Slots on Hood
Screws
5. Lift and attach each motor using 4 screws per motor
making sure they are firmly attached to the motor
plate.
Screws
Motor 1
Screws
Motor 1
6. With both motors installed on canopy, reconnect the
4 cables of the motor to the ones on the hood side
and insert them into the protected area under the
control panel.
Connectors on
Hood Side
7. Mount the metal lid and
tighten the 3 screws to
secure the lid on the hood
body.
Screws
Motor 2
Motor
Screws
Plate
Motor Plate
Motor 2
Screws
Connectors on
Motor Side
Screws
Metal Lid
49-2000930 Rev. 2