Télécharger Imprimer la page

Trotec TTR 1400 Traduction De La Notice Originale page 74

Déshydrateur à adsorption

Publicité

Les langues disponibles

Les langues disponibles

Operation screens of the control module Millenium
EN
1. Start screen
In addition to the contact data this screen also shows the version number of
the installed programme of your Millenium.
Please quote this when contacting.
2. Temperature screen
Display of maximum and actual values for the regeneration and exhaust air
temperatures
MAXIMUM RHZ
Target value regeneration air temperature
ACTUAL RHZ
Actual value regeneration air temperature
MAXIMUM RAL
Target value regeneration exhaust air temperature
ACTUAL RAL
Actual value regeneration exhaust air temperature
3. Temperature and rotor screen
T-RHZ MIN.
Minimum temperature of the regeneration air after
completion of waiting period
DELAY-TIME
Waiting period in seconds
CHECKSUM
Counter for automatic switch-off when hot
ROTORSPEED
Current control value of the rotor speed [1/10 h]
4. Relative humidity screen (optional)
1Ext/2Int/3P
Selection target value external = 1, internal = 2,
control value external = 3
ACT.Moist
Actual value humidity in [% RH]
SetP.Int.
Target value humidity in [% RH], can be modified
SetP.Ext.
Target value external humidity in [% RH], display only
5. Dew point screen (optional)
1Ext/2Int/3P
Selection target value external = 1, internal = 2,
control value external = 3
ACT.Moist
Actual value humidity in [°Cdp]
SetP.Int.
Target value humidity in [°Cdp], can be modified
SetP.Ext.
Target value external humidity in [°Cdp], display only
desiccant dehumidifier TTR 800 / TTR 1400