5. MALFUNCTION ANALYSIS
INDOOR UNIT
5.1 GENERAL IMPACTS OF NON-COMPLIANCE
irregularity
There were power surges?
There are fluorescent lamps?
The indoor unit
The remote control is beyond the scope of maximum
does not receive
distance?
the signal
There are obstacles between remote control and unit?
from the remote
control
The remote is pointed correctly to the receiver?
The display is uneven?
The remote control appears to regulate, positioned
correctly but the U.I. It does not receive the signal
Air intake or outlet blocked?
IThe set temperature has been reached?
No air comes out
It just been turned on the unit in heating mode?
Lack of electricity?
damaged electrical wiring?
The device
does not work
There was a sudden power surge?
Setting the remote control correct?
emits fog
The temperature and the ambient humidity are high?
The unit is in AUTO mode?
Can not be done
change the
temperature
E 'over a temperature request
The range of adjustment?
dirty filter?
Voltage too low?
Cooling are
The set temperature is reached?
not effective
There are no doors or windows open, heat or
thermal bridges?
emission
Dry siphon condensate
bad smells
The unit comes on
Possible interference such as voltage surges, storms,
suddenly
magnetic waves.
noise like
The machine has just been turned on?
gurgling
noise like
The machine has just been turned on or off?
crunch
verification
45
U
Remedy
Cut off the power and feed it after a wait of at least
180sec.
Move the remote closer all'U.I. Turn off fluorescent lamps
and try again.
The maximum distance is 8 m.
Removing obstacles
Replace the remote control and try again.
Check the batteries, replace them if necessary.
Contact supplier.
Remove any obstacles.
After reaching the temperature
set, the UI stops the fan.
To avoid the cold air flow, ventilation is activated only
when the heat exchanger is sufficiently hot.
Attendere fino al suo ripristino.
Replaced by a qualified
Cut off the power and feed it after a wait of at least 180
sec.
To verify
It 'a natural phenomenon. With decreasing temperature
and humidity the phenomenon fades.
The desired temperature can not be changed in AUTO
mode. Change the operating mode.
September temperatures range:
16 ° C ~ 30 ° C
check
check
check
check
Put a little 'of water in the basin. Clean the filter.
Cut off the power and feed it after a wait of at least 180
sec.
Inside the heat exchanger is a change of state of a fluid. It is
a normal phenomenon especially immediately after power
It 'a noise level due to normal expansion of the
components, accentuated in heat pump mode.