Troubleshooting Procedures (cont.)
Symptoms
25. Water splashes off the
drip tray onto the floor.
26. Door will not stay in the
raised position.
1128535-2-B
Probable Causes
H. The secondary seal systems are
not operating properly.
I.
The compressor is not working.
The controller is not working.
J.
A. The brush seal is not installed
or is not adjusted correctly.
B. The bath is not leveled properly.
C. The door gap is too big because
the pulley assembly is not
properly adjusted.
D. Water is splashing over the top
of the seal.
A. One or both counterweights are
not attached.
B. Door bumper needs adjustment.
C. The mounting bracket is not
adjusted properly.
D. There is excessive wear on latch
pin and/or strike plate.
E. The handle/latch mechanism
inside the door is not working.
Recommended Action
H. Call the Customer Care Center
using the information provided on
the back page of this manual.
I.
The compressor needs to be
replaced. Call the Customer Care
Center using the information
provided on the back page of this
manual.
The controller needs to be replaced.
J.
Call the Customer Care Center
using the information provided on
the back page of this manual.
A. Install or adjust the brush seal.
B. Check the back ledge and the sides
of the bath for level. Adjust the feet
until the bath is level if needed.
C. Adjust the pulley assembly inward.
D. Lower the water level when filling
the bath. Reduce sudden
movements when bathing.
A. Attach the counterweight(s).
B. Adjust the door bumper as needed.
C. Adjust the mounting brackets
inward using the slots.
D. Apply a small amount of oil to the
face of the strike plate, replace the
strike plate, or call the Customer
Care Center using the information
provided on the back page of this
manual.
E. Call the Customer Care Center
using the information provided on
the back page of this manual.
46