6
Maintenance
Check for correct leak tightness and function again
after maintenance work and/or replacement of
components.
Have the full face mask checked at least once a year by
trained technical staff for condition and correct
operation (in the event of more than 150 dives per year,
have the check performed twice per year).
To keep the full face mask ready for operation:
– Clean the full face mask.
– From time to time, visually inspect the exhalation
valve of the full face mask by removing it as
described below, checking it for dirt and damage,
and then refitting it.
– Lightly rub the sealing surfaces of the plug-in
connectors (1, 2, 3) with Molykote® M111 silicone
grease after every 20 to 30 dives.
6.1 Maintenance intervals
Work to be per-
Unit part
formed
Cleaning, disin-
fecting
Full face mask
Visual, functional
(complete)
and leak test
Visually inspect
Blow-off valves and
control valves
Replace
Visually inspect
Nose pieces
Replace the O-
rings
O-ring under the
Visually inspect
mask holder
Replace the O-
rings
Retainer clip for the
Check functional-
facepieces
ity
Replace the O-
rings
Other O-rings
Replace
1) Only by authorized specialist personnel.
2) In the event of more than 150 dives, semi-annually.
6.2 Cleaning and disinfecting
NOTICE
Risk of damaging the material!
For cleaning and disinfecting, do not use any solvents
(e.g. acetone or alcohol) or cleaning agents with
scouring particles.
► Only follow the specified procedure and use the
specified cleaning and disinfecting agents. Other
agents, dosages and application times may cause
damage to the product.
CAUTION
Damage to the product and danger to eyes and
skin!
The undiluted cleaning agents may be harmful to health
if they make direct contact with eyes or skin.
► When cleaning or disinfecting the full face mask, do
not rub the inside of the visor. The mask should not
be dried at temperatures above 40 °C. The anti-
fogging coating can be damaged in both cases,
which can result in loss of effectiveness. Wear
goggles and protective gloves when working with
undiluted agents.
For information on appropriate cleaning and
disinfection agents and their specifications, see
document 9100081 at www.draeger.com/IFU.
X
6.2.1 Cleaning
X
1)
X
Clean the full face mask thoroughly after each use.
2)
1. Prepare a cleaning solution consisting of water and
X
X
a cleaning agent.
X
2. Clean all parts using a soft cloth with cleaning
solution.
X
X
3. Thoroughly rinse all parts under running water.
2)
X
Make sure that the ventilated facepieces, inner
mask or bite mouthpiece are cleaned thoroughly
X
X
with hot, running water. Direct the water jet directly
on the exhalation valve from the inside.
2)
X
4. Do not dry the full face mask at temperatures of over
60 °C, do not place rubber parts directly on the
X
X
heating/drying element or in direct sunlight. Observe
the guidelines outlined in DIN ISO 2230 Rubber
2)
X
products – Guidelines for storage and maintenance.
2)
X
Maintenance
en