Connecting the attachments (Fig. 5)
To mount attachments 7, 9, 11, 12, 16, 17 press them
into the pistol (8) and turn them until the lock.
To mount attachments 10, 13, 18 insert these into the
attachment (7) and turn them until they lock.
9.
Operation
The equipment consists of an assembly with a pump,
which is encased in a shock absorbing housing. The
equipment comes with a lance and a non-slip gun (for
an optimal working position), whose shape and config-
uration comply with the applicable regulations.
Commissioning:
Once you have completely assembled the high-pres-
sure cleaner and all connections have been made,
proceed as follows:
Turn on the water supply. Unlock the pistol (8) via the
locking switch (C). Pull back the trigger lever (D) so
that the air in the device can discharge. (Fig. 5)
Switch on the device by setting the on/off switch (3)
to "ON". Next, press the trigger lever (D). (Fig. 1/5)
To switch off, release the trigger lever (D), and the de-
vice switches to stand-by. The high-pressure clean-
er starts again when you press the trigger lever (D).
(Fig. 5)
To switch off the high-pressure cleaner completely, set
the on/off switch (3) to "OFF". (Fig. 1)
Cleaner container (11)
Fill the cleaner container with the corresponding
cleaner. The beam width can be adjusted at the noz-
zle.
Using the attachments (Fig. 1):
R-Nozzle (10): For coarse cleaning work.
Kärcher-adapter (12): Use this adapter to attach
Kärcher brand accessories.
Terrace cleaner (13): For cleaning floor and wall sur-
faces.
Rotating brush (17): For surface cleaning
Cleaning brush (16): For surface cleaning.
H-nozzle (18): For eliminating stubborn dirt.
10. Electrical connections
The electrical motor installed is connected and
ready for operation. The connection complies with
the applicable VDE and DIN provisions.
The customer's mains connection as well as the
extension cable used must also comply with these
regulations.
Damaged electrical connection cable
The insulation on electrical connection cables is of-
ten damaged.
This may have the following causes:
• Passage points, where connection cables are
passed through windows or doors.
• Kinks where the connection cable has been improp-
erly fastened or routed.
• Places where the connection cables have been cut
due to being driven over.
• Insulation damage due to being ripped out of the
wall outlet.
• Cracks due to the insulation ageing.
Such damaged electrical connection cables must not
be used and are life-threatening due to the insulation
damage.
Check the electrical connection cables for damage
regularly. Make sure that the connection cable does
not hang on the power network during the inspection.
Electrical connection cables must comply with the ap-
plicable VDE and DIN provisions. Only use connection
cables with the marking „H05VV-F".
The printing of the type designation on the connection
cable is mandatory.
AC motor
• The mains voltage must be 230 V~
• Extension cables up to 25 m long must have a
cross-section of 1.5 mm
Connections and repairs of electrical equipment may
only be carried out by an electrician.
www.scheppach.com
.
2
GB | 25