Troubleshooting (cont.)
Symptoms
17. Water splashes off the
drip tray onto the floor.
18. Door will not stay in the
raised position.
1128532-5-G
All manuals and user guides at all-guides.com
Probable Causes
H. The wire connections are loose.
The internal wire connections
I.
inside the door are loose.
The primary seal system is not
J.
operating properly or the air
line may be pinched.
K. The secondary seal systems are
not operating properly or the air
line may be pinched.
L. There is an air leak inside the
door.
M. The compressor is not working.
N. The pressure switch inside the
door is not working or is
leaking air.
O. The controller is not working.
A. The brush seal is not installed
or is not adjusted correctly.
B. The bath is not leveled properly. B. Check the back ledge and the sides
C. The door gap is too big because
the pulley assembly is not
properly adjusted.
D. Water is splashing over the top
of the seal.
A. One or both counterweights are
not attached.
B. Door bumper needs adjustment.
C. The mounting bracket is not
adjusted properly.
18
Recommended Action
H1. Check the power cord from the
outlet to the controller.
H2. Check the drain valve power cord
to the controller.
H3. Check the level probe wiring to the
controller.
H4. Check the limit switch wiring to
the controller.
H5. Check the door power cord to the
controller.
Call the Customer Care Center
I.
using the information provided on
the back page of this manual.
Call the Customer Care Center
J.
using the information provided on
the back page of this manual.
K. Call the Customer Care Center
using the information provided on
the back page of this manual.
L. Call the Customer Care Center
using the information provided on
the back page of this manual.
M. The compressor needs to be
replaced. Call the Customer Care
Center using the information
provided on the back page of this
manual.
N. Call the Customer Care Center
using the information provided on
the back page of this manual.
O. The controller needs to be replaced.
Call the Customer Care Center
using the information provided on
the back page of this manual.
A. Install or adjust the brush seal.
of the bath for level. Adjust the feet
until the bath is level if needed.
C. Adjust the pulley assembly inward.
D. Lower the water level when filling
the bath. Reduce sudden
movements when bathing.
A. Attach the counterweight(s).
B. Adjust the door bumper as needed.
C. Adjust the mounting brackets
inward using the slots.
Kohler Co.