Troubleshooting (cont.)
Symptoms
11. The seal will not fully
inflate or the compressor
keeps turning on after
inflation.
Kohler Co.
All manuals and user guides at all-guides.com
Probable Causes
D. One or both of the limit
switches are not making contact
or are damaged.
E. The drain valve is connected to
another 120 V outlet and/or is
not plugged into the controller.
F.
Error code in controller has
been activated (beeping sound
heard).
G. The drain valve is not working.
H. The controller is not working.
A. One or both limit switches are
not making contact or are
damaged.
B. The primary seal system is not
operating properly or the air
line might be pinched.
C. There is air leaking inside the
door.
D. The air pressure switch is not
working or is leaking air.
15
Recommended Action
D1. Adjust the limit switch/switches
until contact is made.
D2. The limit switch/switches need to
be replaced. Call the Customer
Care Center using the information
provided on the back page of this
manual.
E. Plug the drain valve directly into J2
in the controller.
F1. Reset the controller. To do this;
lower the door
quickly tap the door switch 5
times
wait 3 seconds, then tap the
switch 11 times within a 5
second span
the controller should beep 3 to
5 times to indicate the issue
has been resolved, then go
quiet.
F2. If the error code is still activated or
reoccurs, unplug the power and
call the Customer Care Center
using the information provided on
the back page of this manual.
G. Replace the drain valve or call the
Customer Care Center using the
information provided on the back
page of this manual.
H. Replace the controller or call
Customer Care Center using the
information provided on the back
page of this manual.
A1. Adjust the limit switch or switches
until contact is made.
A2. The limit switch needs to be
replaced. Call the Customer Care
Center using the information
provided on the back page of this
manual.
B. Call the Customer Care Center
using the information provided on
the back page of this manual.
C. Call the Customer Care Center
using the information provided on
the back page of this manual.
D. The air pressure switch needs to be
replaced. Call the Customer Care
Center using the information
provided on the back page of this
manual.