7
SPARE PARTS
Before use we advise you to have spare parts
in store, see table B in the appendix of this
manual.
8
TECHNICAL INFORMATION
See for technical specifications table C in
the appendix of this booklet.
9
INSTALLING ACCESSORIES
9.1
Flue (fig. 9)
The heater has a flue stack connection.
1. Push a T-piece (A) directly over the
connection (B).
2. Push the flue pipe (C) on the T-piece.
3. Use three screws to screw the flue pipe
to the T-piece.
Caution
The flue must meet the following
requirements.
The flue must be pointed upwards.
The flue (or any part of it) may not be
positioned horizontally. A 45° angle is
acceptable.
It is not allowed to lenghten the flue
connection horizontally.
When a pipe is used under 45°, pipe
pieces of at least 1 m must be fitted in
front of and at the back of the slanting
pipe.
The flue must stick out at least 0,5 m
above the apex of the building.
Keep the vertical part at the back of the
heater as long as possible before leading
it outside through the wall.
4. Fit the following pipe pieces.
5. Place a cap (D) at the end of the flue.
9.2
Diameter flue
/i
AT 306
150 mm
AT 300 series
AT 307
150 mm
40.020.933 - rev. 04 - 2011
10
EC DECLARATION OF
CONFORMITY
For the EC declaration of conformity, go to
www.thermobile.nl.
English
29