xFUME™ ADVANCED HP 230V – CSA
9.4 Replacing the turbines
Electric shock due to electronic component damage
When replacing carbon brushes and turbines, electrical connections must be disconnected and
reconnected. Fatal electric shock may occur if electronic components become damaged or improperly
uninstalled in the process.
► The carbon brushes and turbines should be replaced only by a qualified electrician.
WARNING
9 Maintenance and cleaning
Remove the upper screws (4×) and the cover.
1
Remove the screws (2× each) and the turbine
2
covers.
Release the grounding cable from the terminal
3
clamps.
Remove the electrical flat plug.
4
Remove the turbines.
5
Insert the new turbines. When doing so, fit the
6
turbines centrally on the base.
Dispose of the turbines in accordance with local
7
regulations.
 12 Disposal on page EN-27
Reverse the steps above to reassemble the system.
8
EN - 23